Fix setting target temperature for single setpoint Matter thermostat (#121011)
parent
52627b9aed
commit
0d0ca22103
|
@ -274,19 +274,13 @@ class MatterClimate(MatterEntity, ClimateEntity):
|
|||
self._attr_hvac_action = HVACAction.FAN
|
||||
case _:
|
||||
self._attr_hvac_action = HVACAction.OFF
|
||||
# update target_temperature
|
||||
if self._attr_hvac_mode == HVACMode.HEAT_COOL:
|
||||
self._attr_target_temperature = None
|
||||
elif self._attr_hvac_mode == HVACMode.COOL:
|
||||
self._attr_target_temperature = self._get_temperature_in_degrees(
|
||||
clusters.Thermostat.Attributes.OccupiedCoolingSetpoint
|
||||
)
|
||||
else:
|
||||
self._attr_target_temperature = self._get_temperature_in_degrees(
|
||||
clusters.Thermostat.Attributes.OccupiedHeatingSetpoint
|
||||
)
|
||||
# update target temperature high/low
|
||||
if self._attr_hvac_mode == HVACMode.HEAT_COOL:
|
||||
supports_range = (
|
||||
self._attr_supported_features
|
||||
& ClimateEntityFeature.TARGET_TEMPERATURE_RANGE
|
||||
)
|
||||
if supports_range and self._attr_hvac_mode == HVACMode.HEAT_COOL:
|
||||
self._attr_target_temperature = None
|
||||
self._attr_target_temperature_high = self._get_temperature_in_degrees(
|
||||
clusters.Thermostat.Attributes.OccupiedCoolingSetpoint
|
||||
)
|
||||
|
@ -296,6 +290,16 @@ class MatterClimate(MatterEntity, ClimateEntity):
|
|||
else:
|
||||
self._attr_target_temperature_high = None
|
||||
self._attr_target_temperature_low = None
|
||||
# update target_temperature
|
||||
if self._attr_hvac_mode == HVACMode.COOL:
|
||||
self._attr_target_temperature = self._get_temperature_in_degrees(
|
||||
clusters.Thermostat.Attributes.OccupiedCoolingSetpoint
|
||||
)
|
||||
else:
|
||||
self._attr_target_temperature = self._get_temperature_in_degrees(
|
||||
clusters.Thermostat.Attributes.OccupiedHeatingSetpoint
|
||||
)
|
||||
|
||||
# update min_temp
|
||||
if self._attr_hvac_mode == HVACMode.COOL:
|
||||
attribute = clusters.Thermostat.Attributes.AbsMinCoolSetpointLimit
|
||||
|
|