core/homeassistant/components/knx/sensor.py

79 lines
2.5 KiB
Python
Raw Normal View History

"""Support for KNX/IP sensors."""
from __future__ import annotations
from typing import Any, Callable, Iterable
from xknx.devices import Sensor as XknxSensor
from homeassistant.components.sensor import DEVICE_CLASSES, SensorEntity
from homeassistant.core import HomeAssistant
from homeassistant.helpers.entity import Entity
from homeassistant.helpers.typing import ConfigType, DiscoveryInfoType, StateType
from homeassistant.util import dt
from .const import ATTR_LAST_KNX_UPDATE, ATTR_SOURCE, DOMAIN
from .knx_entity import KnxEntity
async def async_setup_platform(
hass: HomeAssistant,
config: ConfigType,
async_add_entities: Callable[[Iterable[Entity]], None],
discovery_info: DiscoveryInfoType | None = None,
) -> None:
Stable and asynchronous KNX library. (#8725) * First draft of XKNX module for Home-Assistant * XKNX does now take path of xknx.yaml as parameter * small fix, telegram_received_callback has different signature * changed method of registering callbacks of devices * removed non async command lines from xknx * telegram_received_cb not needed within HASS module * updated requirements * Configuration if XKNX should connect via Routing or Tunneling * bumping version to 0.6.1 * small fix within xknx plugin * bumped version * XKNX-Switches are now BinarySensors and Logic from Sensor was moved to BinarySensor * renamed Outlet to Switch * pylint * configuration of KNX lights via HASS config, yay! * changed name of attribute * Added configuration for xknx to switch component * added support for sensors within hass configuration * added support for climate within hass configuration * Thermostat -> Climate * added configuration support for binary_sensors * renamed Shutter to Cover * added configuration support for cover * restructured file structure according to HASS requirements * pylint * pylint * pylint * pylint * pylint * pylint * updated version * pylint * pylint * pylint * added setpoint support for climate devices * devices are now in a different module * more asyncio :-) * pydocstyle * pydocstyle * added actions to binary_sensor * allow more than one automation * readded requirement * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * xknx now imported as local import * hound *sigh* * lint * 'fixed' coverage. * next try for getting gen_requirements_all.py working * removed blank line * XKNX 0.7.1 with logging functionality, replaced some print() calls with _LOGGER * updated requirements_all.txt * Fixes issue https://github.com/XKNX/xknx/issues/51 * https://github.com/XKNX/xknx/issues/52 added raw access to KNX bus from HASS component. * bumped version - 0.7.3 contains some bugfixes * bumped version - 0.7.3 contains some bugfixes * setting setpoint within climate device has to be async * bumped version to 0.7.4 * bumped version * https://github.com/XKNX/xknx/issues/48 Adding HVAC support. * pylint suggestions * Made target temperature and set point required attributes * renamed value_type to type within sensor configuration * Issue https://github.com/XKNX/xknx/issues/52 : added filter functionality for not flooding the event bus. * suggestions by pylint * Added notify support for knx platform. * logging error if discovery_info is None. * review suggestions by @armills * line too long * Using discovery_info to notifiy component which devices should be added. * moved XKNX automation to main level. * renamed xknx component to knx. * reverted change within .coveragerc * changed dependency * updated docstrings. * updated version of xknx within requirements_all.txt * moved requirement to correct position * renamed configuration attribute * added @callback-decorator and async_prefix. * added @callback decorator and async_ prefix to register_callbacks functions * fixed typo * pylint suggestions * added angle position and invert_position and invert_angle to cover.knx * typo * bumped version within requirements_all.txt * bumped version * Added support for HVAC controller status
2017-09-07 07:11:55 +00:00
"""Set up sensor(s) for KNX platform."""
entities = []
for device in hass.data[DOMAIN].xknx.devices:
2020-08-30 18:13:47 +00:00
if isinstance(device, XknxSensor):
entities.append(KNXSensor(device))
async_add_entities(entities)
Stable and asynchronous KNX library. (#8725) * First draft of XKNX module for Home-Assistant * XKNX does now take path of xknx.yaml as parameter * small fix, telegram_received_callback has different signature * changed method of registering callbacks of devices * removed non async command lines from xknx * telegram_received_cb not needed within HASS module * updated requirements * Configuration if XKNX should connect via Routing or Tunneling * bumping version to 0.6.1 * small fix within xknx plugin * bumped version * XKNX-Switches are now BinarySensors and Logic from Sensor was moved to BinarySensor * renamed Outlet to Switch * pylint * configuration of KNX lights via HASS config, yay! * changed name of attribute * Added configuration for xknx to switch component * added support for sensors within hass configuration * added support for climate within hass configuration * Thermostat -> Climate * added configuration support for binary_sensors * renamed Shutter to Cover * added configuration support for cover * restructured file structure according to HASS requirements * pylint * pylint * pylint * pylint * pylint * pylint * updated version * pylint * pylint * pylint * added setpoint support for climate devices * devices are now in a different module * more asyncio :-) * pydocstyle * pydocstyle * added actions to binary_sensor * allow more than one automation * readded requirement * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * xknx now imported as local import * hound *sigh* * lint * 'fixed' coverage. * next try for getting gen_requirements_all.py working * removed blank line * XKNX 0.7.1 with logging functionality, replaced some print() calls with _LOGGER * updated requirements_all.txt * Fixes issue https://github.com/XKNX/xknx/issues/51 * https://github.com/XKNX/xknx/issues/52 added raw access to KNX bus from HASS component. * bumped version - 0.7.3 contains some bugfixes * bumped version - 0.7.3 contains some bugfixes * setting setpoint within climate device has to be async * bumped version to 0.7.4 * bumped version * https://github.com/XKNX/xknx/issues/48 Adding HVAC support. * pylint suggestions * Made target temperature and set point required attributes * renamed value_type to type within sensor configuration * Issue https://github.com/XKNX/xknx/issues/52 : added filter functionality for not flooding the event bus. * suggestions by pylint * Added notify support for knx platform. * logging error if discovery_info is None. * review suggestions by @armills * line too long * Using discovery_info to notifiy component which devices should be added. * moved XKNX automation to main level. * renamed xknx component to knx. * reverted change within .coveragerc * changed dependency * updated docstrings. * updated version of xknx within requirements_all.txt * moved requirement to correct position * renamed configuration attribute * added @callback-decorator and async_prefix. * added @callback decorator and async_ prefix to register_callbacks functions * fixed typo * pylint suggestions * added angle position and invert_position and invert_angle to cover.knx * typo * bumped version within requirements_all.txt * bumped version * Added support for HVAC controller status
2017-09-07 07:11:55 +00:00
class KNXSensor(KnxEntity, SensorEntity):
Stable and asynchronous KNX library. (#8725) * First draft of XKNX module for Home-Assistant * XKNX does now take path of xknx.yaml as parameter * small fix, telegram_received_callback has different signature * changed method of registering callbacks of devices * removed non async command lines from xknx * telegram_received_cb not needed within HASS module * updated requirements * Configuration if XKNX should connect via Routing or Tunneling * bumping version to 0.6.1 * small fix within xknx plugin * bumped version * XKNX-Switches are now BinarySensors and Logic from Sensor was moved to BinarySensor * renamed Outlet to Switch * pylint * configuration of KNX lights via HASS config, yay! * changed name of attribute * Added configuration for xknx to switch component * added support for sensors within hass configuration * added support for climate within hass configuration * Thermostat -> Climate * added configuration support for binary_sensors * renamed Shutter to Cover * added configuration support for cover * restructured file structure according to HASS requirements * pylint * pylint * pylint * pylint * pylint * pylint * updated version * pylint * pylint * pylint * added setpoint support for climate devices * devices are now in a different module * more asyncio :-) * pydocstyle * pydocstyle * added actions to binary_sensor * allow more than one automation * readded requirement * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * xknx now imported as local import * hound *sigh* * lint * 'fixed' coverage. * next try for getting gen_requirements_all.py working * removed blank line * XKNX 0.7.1 with logging functionality, replaced some print() calls with _LOGGER * updated requirements_all.txt * Fixes issue https://github.com/XKNX/xknx/issues/51 * https://github.com/XKNX/xknx/issues/52 added raw access to KNX bus from HASS component. * bumped version - 0.7.3 contains some bugfixes * bumped version - 0.7.3 contains some bugfixes * setting setpoint within climate device has to be async * bumped version to 0.7.4 * bumped version * https://github.com/XKNX/xknx/issues/48 Adding HVAC support. * pylint suggestions * Made target temperature and set point required attributes * renamed value_type to type within sensor configuration * Issue https://github.com/XKNX/xknx/issues/52 : added filter functionality for not flooding the event bus. * suggestions by pylint * Added notify support for knx platform. * logging error if discovery_info is None. * review suggestions by @armills * line too long * Using discovery_info to notifiy component which devices should be added. * moved XKNX automation to main level. * renamed xknx component to knx. * reverted change within .coveragerc * changed dependency * updated docstrings. * updated version of xknx within requirements_all.txt * moved requirement to correct position * renamed configuration attribute * added @callback-decorator and async_prefix. * added @callback decorator and async_ prefix to register_callbacks functions * fixed typo * pylint suggestions * added angle position and invert_position and invert_angle to cover.knx * typo * bumped version within requirements_all.txt * bumped version * Added support for HVAC controller status
2017-09-07 07:11:55 +00:00
"""Representation of a KNX sensor."""
def __init__(self, device: XknxSensor) -> None:
"""Initialize of a KNX sensor."""
self._device: XknxSensor
super().__init__(device)
@property
def state(self) -> StateType:
Stable and asynchronous KNX library. (#8725) * First draft of XKNX module for Home-Assistant * XKNX does now take path of xknx.yaml as parameter * small fix, telegram_received_callback has different signature * changed method of registering callbacks of devices * removed non async command lines from xknx * telegram_received_cb not needed within HASS module * updated requirements * Configuration if XKNX should connect via Routing or Tunneling * bumping version to 0.6.1 * small fix within xknx plugin * bumped version * XKNX-Switches are now BinarySensors and Logic from Sensor was moved to BinarySensor * renamed Outlet to Switch * pylint * configuration of KNX lights via HASS config, yay! * changed name of attribute * Added configuration for xknx to switch component * added support for sensors within hass configuration * added support for climate within hass configuration * Thermostat -> Climate * added configuration support for binary_sensors * renamed Shutter to Cover * added configuration support for cover * restructured file structure according to HASS requirements * pylint * pylint * pylint * pylint * pylint * pylint * updated version * pylint * pylint * pylint * added setpoint support for climate devices * devices are now in a different module * more asyncio :-) * pydocstyle * pydocstyle * added actions to binary_sensor * allow more than one automation * readded requirement * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * xknx now imported as local import * hound *sigh* * lint * 'fixed' coverage. * next try for getting gen_requirements_all.py working * removed blank line * XKNX 0.7.1 with logging functionality, replaced some print() calls with _LOGGER * updated requirements_all.txt * Fixes issue https://github.com/XKNX/xknx/issues/51 * https://github.com/XKNX/xknx/issues/52 added raw access to KNX bus from HASS component. * bumped version - 0.7.3 contains some bugfixes * bumped version - 0.7.3 contains some bugfixes * setting setpoint within climate device has to be async * bumped version to 0.7.4 * bumped version * https://github.com/XKNX/xknx/issues/48 Adding HVAC support. * pylint suggestions * Made target temperature and set point required attributes * renamed value_type to type within sensor configuration * Issue https://github.com/XKNX/xknx/issues/52 : added filter functionality for not flooding the event bus. * suggestions by pylint * Added notify support for knx platform. * logging error if discovery_info is None. * review suggestions by @armills * line too long * Using discovery_info to notifiy component which devices should be added. * moved XKNX automation to main level. * renamed xknx component to knx. * reverted change within .coveragerc * changed dependency * updated docstrings. * updated version of xknx within requirements_all.txt * moved requirement to correct position * renamed configuration attribute * added @callback-decorator and async_prefix. * added @callback decorator and async_ prefix to register_callbacks functions * fixed typo * pylint suggestions * added angle position and invert_position and invert_angle to cover.knx * typo * bumped version within requirements_all.txt * bumped version * Added support for HVAC controller status
2017-09-07 07:11:55 +00:00
"""Return the state of the sensor."""
return self._device.resolve_state()
2016-11-09 05:00:33 +00:00
@property
def unit_of_measurement(self) -> str | None:
Stable and asynchronous KNX library. (#8725) * First draft of XKNX module for Home-Assistant * XKNX does now take path of xknx.yaml as parameter * small fix, telegram_received_callback has different signature * changed method of registering callbacks of devices * removed non async command lines from xknx * telegram_received_cb not needed within HASS module * updated requirements * Configuration if XKNX should connect via Routing or Tunneling * bumping version to 0.6.1 * small fix within xknx plugin * bumped version * XKNX-Switches are now BinarySensors and Logic from Sensor was moved to BinarySensor * renamed Outlet to Switch * pylint * configuration of KNX lights via HASS config, yay! * changed name of attribute * Added configuration for xknx to switch component * added support for sensors within hass configuration * added support for climate within hass configuration * Thermostat -> Climate * added configuration support for binary_sensors * renamed Shutter to Cover * added configuration support for cover * restructured file structure according to HASS requirements * pylint * pylint * pylint * pylint * pylint * pylint * updated version * pylint * pylint * pylint * added setpoint support for climate devices * devices are now in a different module * more asyncio :-) * pydocstyle * pydocstyle * added actions to binary_sensor * allow more than one automation * readded requirement * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * xknx now imported as local import * hound *sigh* * lint * 'fixed' coverage. * next try for getting gen_requirements_all.py working * removed blank line * XKNX 0.7.1 with logging functionality, replaced some print() calls with _LOGGER * updated requirements_all.txt * Fixes issue https://github.com/XKNX/xknx/issues/51 * https://github.com/XKNX/xknx/issues/52 added raw access to KNX bus from HASS component. * bumped version - 0.7.3 contains some bugfixes * bumped version - 0.7.3 contains some bugfixes * setting setpoint within climate device has to be async * bumped version to 0.7.4 * bumped version * https://github.com/XKNX/xknx/issues/48 Adding HVAC support. * pylint suggestions * Made target temperature and set point required attributes * renamed value_type to type within sensor configuration * Issue https://github.com/XKNX/xknx/issues/52 : added filter functionality for not flooding the event bus. * suggestions by pylint * Added notify support for knx platform. * logging error if discovery_info is None. * review suggestions by @armills * line too long * Using discovery_info to notifiy component which devices should be added. * moved XKNX automation to main level. * renamed xknx component to knx. * reverted change within .coveragerc * changed dependency * updated docstrings. * updated version of xknx within requirements_all.txt * moved requirement to correct position * renamed configuration attribute * added @callback-decorator and async_prefix. * added @callback decorator and async_ prefix to register_callbacks functions * fixed typo * pylint suggestions * added angle position and invert_position and invert_angle to cover.knx * typo * bumped version within requirements_all.txt * bumped version * Added support for HVAC controller status
2017-09-07 07:11:55 +00:00
"""Return the unit this state is expressed in."""
return self._device.unit_of_measurement()
@property
def device_class(self) -> str | None:
"""Return the device class of the sensor."""
device_class = self._device.ha_device_class()
if device_class in DEVICE_CLASSES:
return device_class
Stable and asynchronous KNX library. (#8725) * First draft of XKNX module for Home-Assistant * XKNX does now take path of xknx.yaml as parameter * small fix, telegram_received_callback has different signature * changed method of registering callbacks of devices * removed non async command lines from xknx * telegram_received_cb not needed within HASS module * updated requirements * Configuration if XKNX should connect via Routing or Tunneling * bumping version to 0.6.1 * small fix within xknx plugin * bumped version * XKNX-Switches are now BinarySensors and Logic from Sensor was moved to BinarySensor * renamed Outlet to Switch * pylint * configuration of KNX lights via HASS config, yay! * changed name of attribute * Added configuration for xknx to switch component * added support for sensors within hass configuration * added support for climate within hass configuration * Thermostat -> Climate * added configuration support for binary_sensors * renamed Shutter to Cover * added configuration support for cover * restructured file structure according to HASS requirements * pylint * pylint * pylint * pylint * pylint * pylint * updated version * pylint * pylint * pylint * added setpoint support for climate devices * devices are now in a different module * more asyncio :-) * pydocstyle * pydocstyle * added actions to binary_sensor * allow more than one automation * readded requirement * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * Modifications suggested by hound * xknx now imported as local import * hound *sigh* * lint * 'fixed' coverage. * next try for getting gen_requirements_all.py working * removed blank line * XKNX 0.7.1 with logging functionality, replaced some print() calls with _LOGGER * updated requirements_all.txt * Fixes issue https://github.com/XKNX/xknx/issues/51 * https://github.com/XKNX/xknx/issues/52 added raw access to KNX bus from HASS component. * bumped version - 0.7.3 contains some bugfixes * bumped version - 0.7.3 contains some bugfixes * setting setpoint within climate device has to be async * bumped version to 0.7.4 * bumped version * https://github.com/XKNX/xknx/issues/48 Adding HVAC support. * pylint suggestions * Made target temperature and set point required attributes * renamed value_type to type within sensor configuration * Issue https://github.com/XKNX/xknx/issues/52 : added filter functionality for not flooding the event bus. * suggestions by pylint * Added notify support for knx platform. * logging error if discovery_info is None. * review suggestions by @armills * line too long * Using discovery_info to notifiy component which devices should be added. * moved XKNX automation to main level. * renamed xknx component to knx. * reverted change within .coveragerc * changed dependency * updated docstrings. * updated version of xknx within requirements_all.txt * moved requirement to correct position * renamed configuration attribute * added @callback-decorator and async_prefix. * added @callback decorator and async_ prefix to register_callbacks functions * fixed typo * pylint suggestions * added angle position and invert_position and invert_angle to cover.knx * typo * bumped version within requirements_all.txt * bumped version * Added support for HVAC controller status
2017-09-07 07:11:55 +00:00
return None
@property
def extra_state_attributes(self) -> dict[str, Any] | None:
"""Return device specific state attributes."""
attr: dict[str, Any] = {}
if self._device.last_telegram is not None:
attr[ATTR_SOURCE] = str(self._device.last_telegram.source_address)
attr[ATTR_LAST_KNX_UPDATE] = str(
dt.as_utc(self._device.last_telegram.timestamp)
)
return attr
@property
def force_update(self) -> bool:
"""
Return True if state updates should be forced.
If True, a state change will be triggered anytime the state property is
updated, not just when the value changes.
"""
return self._device.always_callback