2018-04-16 18:31:25 +00:00
|
|
|
"""
|
|
|
|
Platform for a Generic Modbus Thermostat.
|
|
|
|
|
|
|
|
This uses a setpoint and process
|
|
|
|
value within the controller, so both the current temperature register and the
|
|
|
|
target temperature register need to be configured.
|
|
|
|
|
|
|
|
For more details about this platform, please refer to the documentation at
|
|
|
|
https://home-assistant.io/components/climate.modbus/
|
|
|
|
"""
|
|
|
|
import logging
|
|
|
|
import struct
|
|
|
|
|
|
|
|
import voluptuous as vol
|
|
|
|
|
|
|
|
from homeassistant.const import (
|
|
|
|
CONF_NAME, CONF_SLAVE, ATTR_TEMPERATURE)
|
|
|
|
from homeassistant.components.climate import (
|
|
|
|
ClimateDevice, PLATFORM_SCHEMA, SUPPORT_TARGET_TEMPERATURE)
|
2019-02-11 19:00:37 +00:00
|
|
|
from homeassistant.components.modbus import (
|
|
|
|
CONF_HUB, DEFAULT_HUB, DOMAIN as MODBUS_DOMAIN)
|
2018-04-16 18:31:25 +00:00
|
|
|
import homeassistant.helpers.config_validation as cv
|
|
|
|
|
|
|
|
DEPENDENCIES = ['modbus']
|
|
|
|
|
|
|
|
# Parameters not defined by homeassistant.const
|
|
|
|
CONF_TARGET_TEMP = 'target_temp_register'
|
|
|
|
CONF_CURRENT_TEMP = 'current_temp_register'
|
|
|
|
CONF_DATA_TYPE = 'data_type'
|
|
|
|
CONF_COUNT = 'data_count'
|
|
|
|
CONF_PRECISION = 'precision'
|
|
|
|
|
|
|
|
DATA_TYPE_INT = 'int'
|
|
|
|
DATA_TYPE_UINT = 'uint'
|
|
|
|
DATA_TYPE_FLOAT = 'float'
|
|
|
|
|
|
|
|
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend({
|
2019-02-11 19:00:37 +00:00
|
|
|
vol.Optional(CONF_HUB, default=DEFAULT_HUB): cv.string,
|
2018-04-16 18:31:25 +00:00
|
|
|
vol.Required(CONF_NAME): cv.string,
|
|
|
|
vol.Required(CONF_SLAVE): cv.positive_int,
|
|
|
|
vol.Required(CONF_TARGET_TEMP): cv.positive_int,
|
|
|
|
vol.Required(CONF_CURRENT_TEMP): cv.positive_int,
|
|
|
|
vol.Optional(CONF_DATA_TYPE, default=DATA_TYPE_FLOAT):
|
|
|
|
vol.In([DATA_TYPE_INT, DATA_TYPE_UINT, DATA_TYPE_FLOAT]),
|
|
|
|
vol.Optional(CONF_COUNT, default=2): cv.positive_int,
|
|
|
|
vol.Optional(CONF_PRECISION, default=1): cv.positive_int
|
|
|
|
})
|
|
|
|
|
|
|
|
_LOGGER = logging.getLogger(__name__)
|
|
|
|
|
|
|
|
SUPPORT_FLAGS = SUPPORT_TARGET_TEMPERATURE
|
|
|
|
|
|
|
|
|
2018-08-24 14:37:30 +00:00
|
|
|
def setup_platform(hass, config, add_entities, discovery_info=None):
|
2018-04-16 18:31:25 +00:00
|
|
|
"""Set up the Modbus Thermostat Platform."""
|
|
|
|
name = config.get(CONF_NAME)
|
|
|
|
modbus_slave = config.get(CONF_SLAVE)
|
|
|
|
target_temp_register = config.get(CONF_TARGET_TEMP)
|
|
|
|
current_temp_register = config.get(CONF_CURRENT_TEMP)
|
|
|
|
data_type = config.get(CONF_DATA_TYPE)
|
|
|
|
count = config.get(CONF_COUNT)
|
|
|
|
precision = config.get(CONF_PRECISION)
|
2019-02-11 19:00:37 +00:00
|
|
|
hub_name = config.get(CONF_HUB)
|
|
|
|
hub = hass.data[MODBUS_DOMAIN][hub_name]
|
2018-04-16 18:31:25 +00:00
|
|
|
|
2019-02-11 19:00:37 +00:00
|
|
|
add_entities([ModbusThermostat(hub, name, modbus_slave,
|
2018-08-24 14:37:30 +00:00
|
|
|
target_temp_register, current_temp_register,
|
|
|
|
data_type, count, precision)], True)
|
2018-04-16 18:31:25 +00:00
|
|
|
|
|
|
|
|
|
|
|
class ModbusThermostat(ClimateDevice):
|
|
|
|
"""Representation of a Modbus Thermostat."""
|
|
|
|
|
2019-02-11 19:00:37 +00:00
|
|
|
def __init__(self, hub, name, modbus_slave, target_temp_register,
|
2018-04-16 18:31:25 +00:00
|
|
|
current_temp_register, data_type, count, precision):
|
|
|
|
"""Initialize the unit."""
|
2019-02-11 19:00:37 +00:00
|
|
|
self._hub = hub
|
2018-04-16 18:31:25 +00:00
|
|
|
self._name = name
|
|
|
|
self._slave = modbus_slave
|
|
|
|
self._target_temperature_register = target_temp_register
|
|
|
|
self._current_temperature_register = current_temp_register
|
|
|
|
self._target_temperature = None
|
|
|
|
self._current_temperature = None
|
|
|
|
self._data_type = data_type
|
|
|
|
self._count = int(count)
|
|
|
|
self._precision = precision
|
|
|
|
self._structure = '>f'
|
|
|
|
|
|
|
|
data_types = {DATA_TYPE_INT: {1: 'h', 2: 'i', 4: 'q'},
|
|
|
|
DATA_TYPE_UINT: {1: 'H', 2: 'I', 4: 'Q'},
|
|
|
|
DATA_TYPE_FLOAT: {1: 'e', 2: 'f', 4: 'd'}}
|
|
|
|
|
|
|
|
self._structure = '>{}'.format(data_types[self._data_type]
|
|
|
|
[self._count])
|
|
|
|
|
|
|
|
@property
|
|
|
|
def supported_features(self):
|
|
|
|
"""Return the list of supported features."""
|
|
|
|
return SUPPORT_FLAGS
|
|
|
|
|
|
|
|
def update(self):
|
|
|
|
"""Update Target & Current Temperature."""
|
|
|
|
self._target_temperature = self.read_register(
|
|
|
|
self._target_temperature_register)
|
|
|
|
self._current_temperature = self.read_register(
|
|
|
|
self._current_temperature_register)
|
|
|
|
|
|
|
|
@property
|
|
|
|
def name(self):
|
|
|
|
"""Return the name of the climate device."""
|
|
|
|
return self._name
|
|
|
|
|
|
|
|
@property
|
|
|
|
def current_temperature(self):
|
|
|
|
"""Return the current temperature."""
|
|
|
|
return self._current_temperature
|
|
|
|
|
|
|
|
@property
|
|
|
|
def target_temperature(self):
|
|
|
|
"""Return the temperature we try to reach."""
|
|
|
|
return self._target_temperature
|
|
|
|
|
|
|
|
def set_temperature(self, **kwargs):
|
|
|
|
"""Set new target temperature."""
|
|
|
|
target_temperature = kwargs.get(ATTR_TEMPERATURE)
|
|
|
|
if target_temperature is None:
|
|
|
|
return
|
|
|
|
byte_string = struct.pack(self._structure, target_temperature)
|
|
|
|
register_value = struct.unpack('>h', byte_string[0:2])[0]
|
|
|
|
|
|
|
|
try:
|
|
|
|
self.write_register(self._target_temperature_register,
|
|
|
|
register_value)
|
|
|
|
except AttributeError as ex:
|
|
|
|
_LOGGER.error(ex)
|
|
|
|
|
|
|
|
def read_register(self, register):
|
|
|
|
"""Read holding register using the modbus hub slave."""
|
|
|
|
try:
|
2019-02-11 19:00:37 +00:00
|
|
|
result = self._hub.read_holding_registers(self._slave, register,
|
|
|
|
self._count)
|
2018-04-16 18:31:25 +00:00
|
|
|
except AttributeError as ex:
|
|
|
|
_LOGGER.error(ex)
|
|
|
|
byte_string = b''.join(
|
|
|
|
[x.to_bytes(2, byteorder='big') for x in result.registers])
|
|
|
|
val = struct.unpack(self._structure, byte_string)[0]
|
|
|
|
register_value = format(val, '.{}f'.format(self._precision))
|
|
|
|
return register_value
|
|
|
|
|
|
|
|
def write_register(self, register, value):
|
|
|
|
"""Write register using the modbus hub slave."""
|
2019-02-11 19:00:37 +00:00
|
|
|
self._hub.write_registers(self._slave, register, [value, 0])
|