2016-02-10 16:32:18 +00:00
"""
Provides a sensor to track various status aspects of a UPS.
2016-02-12 06:54:25 +00:00
For more details about this platform, please refer to the documentation at
https://home-assistant.io/components/sensor.apcupsd/
2016-02-10 16:32:18 +00:00
"""
import logging
2016-08-30 19:34:33 +00:00
import voluptuous as vol
from homeassistant.components.sensor import PLATFORM_SCHEMA
import homeassistant.helpers.config_validation as cv
2016-02-19 05:27:50 +00:00
from homeassistant.components import apcupsd
2016-08-30 19:34:33 +00:00
from homeassistant.const import (TEMP_CELSIUS, CONF_RESOURCES)
2016-02-10 16:32:18 +00:00
from homeassistant.helpers.entity import Entity
2016-08-30 19:34:33 +00:00
_LOGGER = logging.getLogger(__name__)
2016-02-10 16:32:18 +00:00
DEPENDENCIES = [apcupsd.DOMAIN]
SENSOR_PREFIX = 'UPS '
SENSOR_TYPES = {
'alarmdel': ['Alarm Delay', '', 'mdi:alarm'],
'ambtemp': ['Ambient Temperature', '', 'mdi:thermometer'],
'apc': ['Status Data', '', 'mdi:information-outline'],
'apcmodel': ['Model', '', 'mdi:information-outline'],
'badbatts': ['Bad Batteries', '', 'mdi:information-outline'],
'battdate': ['Battery Replaced', '', 'mdi:calendar-clock'],
'battstat': ['Battery Status', '', 'mdi:information-outline'],
'battv': ['Battery Voltage', 'V', 'mdi:flash'],
'bcharge': ['Battery', '%', 'mdi:battery'],
'cable': ['Cable Type', '', 'mdi:ethernet-cable'],
'cumonbatt': ['Total Time on Battery', '', 'mdi:timer'],
'date': ['Status Date', '', 'mdi:calendar-clock'],
'dipsw': ['Dip Switch Settings', '', 'mdi:information-outline'],
'dlowbatt': ['Low Battery Signal', '', 'mdi:clock-alert'],
'driver': ['Driver', '', 'mdi:information-outline'],
'dshutd': ['Shutdown Delay', '', 'mdi:timer'],
'dwake': ['Wake Delay', '', 'mdi:timer'],
'endapc': ['Date and Time', '', 'mdi:calendar-clock'],
'extbatts': ['External Batteries', '', 'mdi:information-outline'],
'firmware': ['Firmware Version', '', 'mdi:information-outline'],
'hitrans': ['Transfer High', 'V', 'mdi:flash'],
'hostname': ['Hostname', '', 'mdi:information-outline'],
'humidity': ['Ambient Humidity', '%', 'mdi:water-percent'],
'itemp': ['Internal Temperature', TEMP_CELSIUS, 'mdi:thermometer'],
'lastxfer': ['Last Transfer', '', 'mdi:transfer'],
'linefail': ['Input Voltage Status', '', 'mdi:information-outline'],
'linefreq': ['Line Frequency', 'Hz', 'mdi:information-outline'],
'linev': ['Input Voltage', 'V', 'mdi:flash'],
'loadpct': ['Load', '%', 'mdi:gauge'],
'lotrans': ['Transfer Low', 'V', 'mdi:flash'],
'mandate': ['Manufacture Date', '', 'mdi:calendar'],
'masterupd': ['Master Update', '', 'mdi:information-outline'],
'maxlinev': ['Input Voltage High', 'V', 'mdi:flash'],
'maxtime': ['Battery Timeout', '', 'mdi:timer-off'],
'mbattchg': ['Battery Shutdown', '%', 'mdi:battery-alert'],
'minlinev': ['Input Voltage Low', 'V', 'mdi:flash'],
'mintimel': ['Shutdown Time', '', 'mdi:timer'],
'model': ['Model', '', 'mdi:information-outline'],
'nombattv': ['Battery Nominal Voltage', 'V', 'mdi:flash'],
'nominv': ['Nominal Input Voltage', 'V', 'mdi:flash'],
'nomoutv': ['Nominal Output Voltage', 'V', 'mdi:flash'],
'nompower': ['Nominal Output Power', 'W', 'mdi:flash'],
'numxfers': ['Transfer Count', '', 'mdi:counter'],
'outputv': ['Output Voltage', 'V', 'mdi:flash'],
'reg1': ['Register 1 Fault', '', 'mdi:information-outline'],
'reg2': ['Register 2 Fault', '', 'mdi:information-outline'],
'reg3': ['Register 3 Fault', '', 'mdi:information-outline'],
'retpct': ['Restore Requirement', '%', 'mdi:battery-alert'],
'selftest': ['Last Self Test', '', 'mdi:calendar-clock'],
'sense': ['Sensitivity', '', 'mdi:information-outline'],
'serialno': ['Serial Number', '', 'mdi:information-outline'],
'starttime': ['Startup Time', '', 'mdi:calendar-clock'],
'statflag': ['Status Flag', '', 'mdi:information-outline'],
'status': ['Status', '', 'mdi:information-outline'],
'stesti': ['Self Test Interval', '', 'mdi:information-outline'],
'timeleft': ['Time Left', '', 'mdi:clock-alert'],
'tonbatt': ['Time on Battery', '', 'mdi:timer'],
'upsmode': ['Mode', '', 'mdi:information-outline'],
'upsname': ['Name', '', 'mdi:information-outline'],
'version': ['Daemon Info', '', 'mdi:information-outline'],
'xoffbat': ['Transfer from Battery', '', 'mdi:transfer'],
'xoffbatt': ['Transfer from Battery', '', 'mdi:transfer'],
'xonbatt': ['Transfer to Battery', '', 'mdi:transfer'],
}
2016-02-10 16:32:18 +00:00
SPECIFIC_UNITS = {
'ITEMP': TEMP_CELSIUS
}
INFERRED_UNITS = {
' Minutes': 'min',
' Seconds': 'sec',
' Percent': '%',
' Volts': 'V',
' Watts': 'W',
' Hz': 'Hz',
' C': TEMP_CELSIUS,
' Percent Load Capacity': '%',
2016-02-10 16:32:18 +00:00
}
2016-08-30 19:34:33 +00:00
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend({
vol.Required(CONF_RESOURCES, default=[]):
vol.All(cv.ensure_list, [vol.In(SENSOR_TYPES)]),
})
2016-02-10 16:32:18 +00:00
def setup_platform(hass, config, add_entities, discovery_info=None):
"""Set up the APCUPSd sensors."""
entities = []
2016-08-30 19:34:33 +00:00
for resource in config[CONF_RESOURCES]:
sensor_type = resource.lower()
if sensor_type not in SENSOR_TYPES:
SENSOR_TYPES[sensor_type] = [
sensor_type.title(), '', 'mdi:information-outline']
if sensor_type.upper() not in apcupsd.DATA.status:
_LOGGER.warning(
"Sensor type: %s does not appear in the APCUPSd status output",
sensor_type)
entities.append(APCUPSdSensor(apcupsd.DATA, sensor_type))
add_entities(entities, True)
2016-02-10 16:32:18 +00:00
def infer_unit(value):
2016-03-08 15:46:34 +00:00
"""If the value ends with any of the units from ALL_UNITS.
Split the unit off the end of the value and return the value, unit tuple
pair. Else return the original value and None as the unit.
2016-02-10 16:32:18 +00:00
"""
from apcaccess.status import ALL_UNITS
for unit in ALL_UNITS:
if value.endswith(unit):
return value[:-len(unit)], INFERRED_UNITS.get(unit, unit.strip())
2016-02-10 16:32:18 +00:00
return value, None
class APCUPSdSensor(Entity):
2016-03-08 15:46:34 +00:00
"""Representation of a sensor entity for APCUPSd status values."""
def __init__(self, data, sensor_type):
2016-03-08 15:46:34 +00:00
"""Initialize the sensor."""
self._data = data
self.type = sensor_type
self._name = SENSOR_PREFIX + SENSOR_TYPES[sensor_type][0]
self._unit = SENSOR_TYPES[sensor_type][1]
2016-02-10 16:32:18 +00:00
self._inferred_unit = None
self._state = None
2016-02-10 16:32:18 +00:00
@property
def name(self):
2016-03-08 15:46:34 +00:00
"""Return the name of the UPS sensor."""
return self._name
@property
def icon(self):
"""Icon to use in the frontend, if any."""
return SENSOR_TYPES[self.type][2]
2016-02-10 16:32:18 +00:00
@property
def state(self):
2016-03-08 15:46:34 +00:00
"""Return true if the UPS is online, else False."""
2016-02-10 16:32:18 +00:00
return self._state
@property
def unit_of_measurement(self):
2016-03-08 15:46:34 +00:00
"""Return the unit of measurement of this entity, if any."""
if not self._unit:
2016-02-10 16:32:18 +00:00
return self._inferred_unit
return self._unit
def update(self):
2016-02-23 05:21:49 +00:00
"""Get the latest status and use it to update our sensor state."""
if self.type.upper() not in self._data.status:
self._state = None
self._inferred_unit = None
else:
self._state, self._inferred_unit = infer_unit(
self._data.status[self.type.upper()])