Combination of mbed 2 builds (~40 minutes), littlefs testing (~15
minutes), and miscellaneous testing pushed the current CI over
Travis's limit of 1 hour per job.
However, by using Travis's matrix includes, we can spin up different
jobs for the various logical components being tested.
Not all devices have enough heap to fit a simulated heap block device,
however using a simulated heap block device is preferred if available
(reduced flash wear, faster testing).
Added MBED_TEST_SIM_BLOCKDEVICE for tests that only need a simulated
block device (wear_leveling + resilience), and added support for targets
that are known to have enough heap.
GattServer::write on Nordic's targets use sd_ble_gatts_hvx to send an
handle value Notification or Indication; This function can fail if the
connection handle is invalid or if Updates are not enabled for this
connection.
This patch workaround those limitations.
Call to osThreadTerminate is guarded by local_id check, to avoid parameter error fault when deleting or terminating Thread object that was not started.
Timer code was written based on integer multiple HF clock frequencies. EFR32 doesn't conform to that (38.4), and so the timestamp ticks were off by 1%. Enough to trip up some CI tests on TB_SENSE_12 (#5496)
Need to avoid a TX packet error from messing up the TX FIFO. Since this API will return busy if a packet is in transmission anyways, this is acceptable.
- serial_init, serial_free and serial_baud function moved from serial_device.c (specific to each STM32 family) to serial_api.c (common STM32 file)
- default baudrate value was hardcoded to 9600
- Value is set now to MBED_CONF_PLATFORM_STDIO_BAUD_RATE for STDIO
- Value is set now to MBED_CONF_PLATFORM_DEFAULT_SERIAL_BAUD_RATE for other use
- UART init will not be stopped before calling serial_baud function
This patch handles the case of SPI slave mode without MISO (NC).
In case MISO is not connected, we consider that SPI will be configured in
3 wires mode (CLK / MOSI / CS, but no MISO). In this case, the MOSI line
is bi-directional : SPI_DIRECTION_1LINE.
But as this is not supported yet in slave mode, we force it to
SPI_DIRECTION_2LINES. In this case slave SPI will receive data on MOSI
but nothing will be sent back to master as MISO is not connected.