Commit Graph

14 Commits (aac3437a22ff2831080f1e7e50546335c6a6a400)

Author SHA1 Message Date
Filip Jagodzinski 2b4b64fafd Tests: USB: Fix Python 3 compatibility
Use integer division explicitly in basic test.
Convert bytes to str for Python 3 in serial test.
2019-09-30 10:21:16 +02:00
Russ Butler 6527cf2bad Update files to include SPDX-License-Identifier
Update the header of all files to use a newer license template which
includes SPDX-License-Identifier.
2019-02-22 10:53:24 -06:00
Filip Jagodzinski 7db3a8a34a Tests: USB: DTR fix for Linux hosts
A DTR line is used to signal that the host has configured a terminal and
is ready to transmit and receive data from the USB CDC/Serial device.
When this test suite is run with the use of a Linux host, a workaround has
to be used to overcome some platform specific DTR line behavior.
Every time the serial port file descriptor is opened, the DTR line is
asserted until the terminal attributes are set.
As a consequence, the device receives a premature DTR signal with a
duration of 200-500 us before the correct, long-lasting DTR signal set by
the host-side test script. (tested on the Linux kernel 4.15.0)

The solution is to wait for the first DTR spike, ignore it, and wait for
the correct DTR signal again.
2019-02-22 10:53:21 -06:00
Russ Butler 930b29dd83 Tests: USB: Increase serial open retries
Double the number of attempts that are made to open a serial port.
This makes tests run more reliably on Windows.
2019-02-22 10:53:21 -06:00
Russ Butler 8f72f314d7 Tests: USB: Use DTR to make Serial tests reliable
Update the serial host test to set DTR low before opening a serial
port. Set DTR high once the serial object is ready. This ensures that
no data is sent by the device until the host is ready.
2019-02-22 10:53:21 -06:00
Filip Jagodzinski 31fe3ee11e Tests: USB: Increas the size of RX CDC test data
This ensures the flow control is tested.
2019-02-22 10:53:21 -06:00
Filip Jagodzinski 53f7cd5561 Tests: USB: Fix Windows USB SN handling 2019-02-22 10:53:21 -06:00
Filip Jagodzinski 3d4d10191c Tests: USB: Update code comments 2019-02-22 10:53:21 -06:00
Filip Jagodzinski edf360d2fc Tests: USB: Use SN generated by the host machine 2019-02-22 10:53:21 -06:00
Filip Jagodzinski dbfd43a098 Tests: USB: Wait before closing host's port
This delay eliminates the possibility of the device detecting the port
being closed when still waiting for data.
2019-02-22 10:53:20 -06:00
Filip Jagodzinski 7b80cb6586 Tests: USB: Add Serial test for line coding change 2019-02-22 10:53:20 -06:00
Filip Jagodzinski bf3aa29e0b Tests: USB: Use the serial number to find device
Use the USB device SN instead of VID & PID to find the device port name
on the host system.
2019-02-22 10:53:20 -06:00
Filip Jagodzinski 7a4b36c37f Tests: USB: Add tests for Serial class. 2019-02-22 10:53:20 -06:00
Filip Jagodzinski 3ed7d8139b Tests: USB: Add tests for CDC class. 2019-02-22 10:53:20 -06:00