Add a config option for the following values:
MBED_SYS_STATS_ENABLED
MBED_STACK_STATS_ENABLED
MBED_CPU_STATS_ENABLED
MBED_HEAP_STATS_ENABLED
MBED_THREAD_STATS_ENABLED
MBED_CONF_APP_MAIN_STACK_SIZE
MBED_CONF_APP_TIMER_THREAD_STACK_SIZE
MBED_CONF_APP_IDLE_THREAD_STACK_SIZE
MBED_CONF_APP_THREAD_STACK_SIZE
To maintain backwards compatibility inside the RTOS both
APP and RTOS config values can be used.
### Description
Now that we are delegating the help text to `device_managment.py`,
it should print out help as if it's invoked with `mbed device-management`.
This PR changes the argument parser and the help text to do just that.
### Pull request type
[x] Fix
[ ] Refactor
[ ] Target update
[ ] Functionality change
[ ] Breaking change
1. Add Pin defines for missing PWM pins
2. Update the hal to account for the number of PWM instances
3. Fix the register reload policy
4. Configure the XBAR to put the PWM fault inputs in inactive state
Signed-off-by: Mahesh Mahadevan <mahesh.mahadevan@nxp.com>
Developer API keys don't have the privileges required to get information about their owners. To correct for this, remove user name reporting and use the API key `owner_id` directly.
Fixes: IOTAUTH-1686
While performing compliance tests with an industry tester, we realized
that there was no need for any extra handling code for the compliance
tests. The tests would run fine, if we only have a handling application.
However, in normal operation we wouldn't like the network to send us any
traffic on compliance testing port. To mitigate that, on the reception
path we filter out any traffic on compliance testing port if compliance
testing is not underway. User should define LORAWAN_COMPLIANCE_TEST macro
in mbed_app.json to enable traffic on compliance test port.
### Description
`mbed dm` will now accept the Pelion Device Management API Key and
Host on the command line with the following switches:
* `-a`, `--api-key` accepts the API Key
* `-S` (note capitol), `--server-address` accepts the Host
This is consistant with manifest tool parameters
Resolves https://github.com/ARMmbed/mbed-cli/issues/745
### Pull request type
[x] Fix
[ ] Refactor
[ ] Target update
[ ] Functionality change
[ ] Breaking change
This commit fixes two bugs related to ADRAckReq:
- adr_ack_counter must be incremented for all uplink messages (not just confirmed)
- When ADR_ACK_LIMIT + ADR_ACK_DELAY has been reached, stack decreased used
datarate twice.
If us_ticker/lp_ticker is scheduled and then the interrupt is disabled, the originally scheduled
interrupt may still become pending. If this occurs, then an interrupt will fire twice on the next
call to us_ticker_set_interrupt/lp_ticker_set_interrupt - once immediately and then a second time
at the appropriate time.
This patch prevents the first interrupt by clearing interrupts in
us_ticker_set_interrupt/lp_ticker_set_interrupt before calling NVIC_EnableIRQ.
Code had mixed up order of 'c' and 'n' arguments to memset().
Fix this.
Spotted-by: kjbracey-arm & a GCC profile without "-fno-builtin"
Related GCC warnings:
---8<---8<----
[Warning] mbed_error.c@123,5: 'memset' used with constant zero length parameter; this could be due to transposed parameters [-Wmemset-transposed-args]