Contains one error fix:
IOTCLT-2469 CoAP UDP retransmission does not work for blocks after first one for requests (Eg. registration POST)
NOTE! These are internal changes required for cloud client. This has no direct relevance to any mbed-os functionality.
Simplify tickers to stop emulating 1us ticks by using native timer resolutions.
Implement ticker get info functions.
Separate rtc and lp ticker init status by implementing separate functions.
Simplify tickers to stop emulating 1us ticks by using native timer resolutions.
Implement ticker get info functions.
Separate rtc and lp ticker init status by implementing separate functions.
Add mbed_critical include file to disable compiler warning messages.
MTB_ADV_WISE_1530 and MTB_USI_WM_BN_BM_22 includes same usi chip,
so common USI_WM_BN_BM_22 target has been created.
MTB_ADV_WISE_1530 and MTB_USI_WM_BN_BM_22 are inheting the common usi target
Bug was reported by @tpet93 and it was correctly diagnosed that channels
were not being set in the phy_params structure. This commit fixes the bug
and sets up channels correctly.
Since revision 5499db1 (mbed-os-5.6.0) a hardfault occurs after a power-cycle.
It doesn't occur after a reset when the application has been downloaded using
drag-and-drop or via debugger. This is probably the reason why this problem
isn't detected when testing new mbed releases.
The hardfault occured in hal_sleep(). Adding a __NOP after __WFI solves the
problem although I don't fully understand why.
- Revision ca661f9 is the last revision where the problem doesn't occur.
- The problem doesn't occur when compiling with GCC instead of ARM compiler
- This issue describes a similar, but not identical problem and led me to test adding a __NOP: https://github.com/ARMmbed/mbed-os/issues/5065