- Store ACK's also into duplicate info list.
- ROM size optimization. Flash size has gone down ~1100 bytes.
**Closed issues:**
- IOTCLT-3592 - Client does not handle Duplicate ACK messages during blockwise registration correctly
Prevent compilation issues when someone has included <stdint.h> before
a header file that needs to include <ns_list.h>.
Some toolchains like ARM C 5 will not provide UINT_FAST8_MAX in C++
unless __STDC_LIMIT_MACROS is defined, and if this was not defined the
first time <stdint.h> was included, it's too late.
We can get the maximum value for our unsigned list offset by casting -1
to it, thanks to modulo arithmetic.
Make sn_coap_protocol_linked_list_duplication_info_remove API to public. User might want to delete some messages from the duplicate list.
Enable support for unified client configuration.
- Remove dependency to yotta tool
- Do not remove stored (GET) blockwise message when EMPTY ACK received. When non piggybacked response mode is used original GET request must not be removed from the stored message list.Message is needed for building the next (GET) blockwise message.
- Move definitions to sn_config.h
EMPTY response should not be stored to blockwise list.
An Empty message only contains the 4-byte header so it does not require any blockwise operations.
This will fix unneseccary message sending timeouts which leads mbed cloud client to do unnecessary
reconnections which increases the network traffic.
Currently there are two issues which prevent building Mbed OS with
-std=gnu++11 when using Arm Compiler 6:
* NanostackRfPhys2lp.cpp contains a narrowing conversion in a braced
initializer list
* ns_types.h includes <stdalign.h> which Arm Compiler 6 currently
does not provide
This patch fixes both issues. The first one is fixed by changing the
underlying type of the corresponding enumeration when the code is
compiled as C++11. The second issue is worked around by avoiding the
use of <stdalign.h> header for Arm Compiler versions prior to 6.12.
- Fix handling of duplicate blockwise ACK's
CoAP data buffer was not added into duplication info store when creating response for blockwise request.
This leads to case where whole bootstrap flow just timeouts if received any duplicate messages during blockwise operation.
Fixes error: IOTCLT-3188 - UDP connection fails for lost ACK sending
- Remove error trace when building reset message without options
This makes it possible to build the reset message without allocating option or getting error message.