Add also default weak version of spi_get_capabilities() which provides default/most common SPI parameters.
This function can be replaced if a specific target has different capabilities.
* Refactor some headers to use relative path from Mbed OS root.
* Refactor some data types to compile on 64bit machines.
* Refactor some debug traces to use mbed_trace.
The QSPI spec allows alt to be any size that is a multiple of the
number of data lines. For example, Micron's N25Q128A uses only a
single alt cycle for all read modes (1, 2, or 4 bits depending on
how many data lines are in use).
The contents of the usb directory were moved to appropriate locations and the usb directory removed.
* Public USB headers moved under drivers/
* Internal USB headers moved under drivers/internal/
* USB Source code moved under drivers/source/usb/
* Moved usb/device/hal/ under hal/usb/
* Moved usb/device/USBPhy/ under hal/usb/
* Merged usb/device/targets/ into targets/
* Separated public and private USB API documentation under Doxygen groups drivers-public-api and drivers-internal-api.
Separate drivers, events, and rtos internal APIs from public APIs.
* Move source files to source subdirs
* Move internal headers to internal subdirs
* Add Doxygen comments for documenting internal and public APIs
* Remove source code from header files in order to remove include pre-processor directives
that included header files not directly used by said header files
* Explicitly include header files instead of implicit inclusions via third-party header files.
Release Notes
This will break user code that was using an internal API as the internal header files have been moved.
This will only break if the user was including the header file using a namespace (i.e #include "foo/bar.h" instead of #include "bar.h"
This change is required by the Samsung S111(S5JS100). On this board timer clock used for us ticker operates at 26MHz.
According to current requirements, 8 MHz is the top limit for us ticker timer.
This change relaxes top limit to 100 MHz, but only for 32-bit timers.
Ticker common layer schedules one interrupt per timer rollover to trace elapsed time. We need to ensure that this operation is not performed too frequently. I.e. in case of 16-bit timer at 32 MHz, the timer rollover will happen after ~2 ms. This may cause that there will be no time for other tasks. That is why we increase the top limit, but only for 32-bit timers.
Functions related to serial flow control should not be exposed
if DEVICE_SERIAL_FC is not defined
* serial_set_flow_control,
* serial_cts_pinmap,