Edit ScanParameters.h

Edit file, mostly to fix typos.
pull/8738/head
Amanda Butler 2018-11-26 19:18:24 -06:00 committed by GitHub
parent fa784c2aff
commit d00ad8bc96
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 10 additions and 10 deletions

View File

@ -44,8 +44,8 @@ namespace ble {
* requests to the advertiser that respond with a scan response. It is possible
* to select what type of address is used to issue the scan request.
*
* With Bluetooth 5, devices can advertise on more physical channels and by
* extension they can scan on more physical channel. It is possible to define
* With Bluetooth 5, devices can advertise on more physical channels, and by
* extension, they can scan on more physical channels. It is possible to define
* independent scan parameters for every scannable physical channel.
*/
class ScanParameters {
@ -58,7 +58,7 @@ public:
/**
* Construct a phy_configuration_t.
* @param scan_interval The scan interval.
* @param scan_window The scan window
* @param scan_window The scan window.
* @param active_scanning True if scan request should be sent and false
* otherwise.
*/
@ -107,12 +107,12 @@ public:
};
/**
* Construct a ScanParameters object that operate on a selected phy.
* Construct a ScanParameters object that operates on a selected PHY.
*
* @param phy The phy to configure.
* @param scan_interval The scan interval.
* @param scan_window The scan window.
* @param active_scanning active scanning flag
* @param active_scanning active scanning flag.
* @param own_address_type Address type used in scan requests.
* @param scanning_filter_policy Filter applied.
*/
@ -159,7 +159,7 @@ public:
/**
* Set the filter to apply during scanning.
* @param filter_policy The filter to apply during scannong.
* @param filter_policy The filter to apply during scanning.
* @return A reference to this object.
*/
ScanParameters &setFilter(scanning_filter_policy_t filter_policy)
@ -177,7 +177,7 @@ public:
}
/**
* Enable or disable phys that should be used during scanning .
* Enable or disable PHYs that should be used during scanning.
* @param enable_1m True to enable the 1M phy and false to disable it.
* @param enable_coded True to enable the coded phy and false to disable it.
* @return A reference to this object.
@ -190,7 +190,7 @@ public:
}
/**
* Get the phys to use during scanning.
* Get the PHYs to use during scanning.
*/
phy_set_t getPhys() const
{
@ -226,7 +226,7 @@ public:
}
/**
* Set the coded phy scan configuration.
* Set the coded PHY scan configuration.
* @param interval The scan interval to use.
* @param window The scan window to use.
* @param active_scanning The active scanning flag.
@ -246,7 +246,7 @@ public:
}
/**
* Get the coded phy scan configuration.
* Get the coded PHY scan configuration.
*/
phy_configuration_t getCodedPhyConfiguration() const
{